Larsen Fire Extinguishers

MP SERIES Multi-Purpose Dry Chemical

These units contain specially fluidized and siliconized mono ammonium phosphate powder which smothers and breaks the chain reaction on Class B fires, fuses and insulates Class A fires, and as a non-conductor of electricity, is effective on Class C fires.

Larsen fire extinguishers

DC SERIES Regular Dry Chemical

These units contain specially siliconized sodium bicarbonate powder with free flowing and non-caking additives, suitable for fire in flammable liquids, and energized electrical equipment. NOTE: Since as of July 1, 1998, all new extinguishers installed in restaurant kitchens must be K class rated, the DC Series no longer is recommended for use in kitchen areas.

All multi-purpose, regular or dry chemical units feature:

  • Heavy Duty DOT Steel Cylinders
  • Rugged Metal Valves and Siphon Tubes
  • Replaceable Molded Valve Stem Seals
  • Corrosion and Impact Resistant Polyester/Epoxy Paint Finish
  • Pull Pin-Upright Squeeze Grip Operation
  • Approved to -65コF
  • Non-Toxic
  • Pressure Gauges
  • Contact Factory if Non-Ferrous Cylinders are Required

WC SERIES Wet Chemical

Wet Chemical units are designed specifically for kitchen grease fire hazards and meet the new K class listing now required for all extinguishers installed in restaurant kitchens. They contain a special potassium acetate based, low PH agent, which leaves no chemical residue to clean up. The spray applicator wand keeps the operator at a safe distance from the fire. Larger 2½ gallon unit with identical U.L. rating is available for a limited time. (shipped uncharged)

PW SERIES Pressurized Water

This unit is ideally suited for all industrial and commercial applications, where easy to use, positive on-off operation is important. Water is used as the extinguishing agent, making it highly effective on deep seated Class A fires (shipped empty).

WM SERIES Water Mist

This unit is designed for use wherever there is a Class A hazard near electrical equipment and the environment is of paramount concern. The extinguishing agent is distilled water, and the wand provides greatest operator safety. There is no risk of electrical conductivity or thermal or static shock. Ideal for use in health care, data processing, telecommunication, and clean room facilities. (shipped empty)

CD SERIES Carbon Dioxide

These units contain liquid carbon dioxide under pressure. It is discharged as a white cloud of “snow”, which effectively smothers a fire. Carbon dioxide is a clean, non-conductor of electricity for Class B and C fires.

  • Absolutely Rust-Free Aluminum Cylinders
  • Up to 30% Lighter
  • O-Ring Seal, Straight Thread Brass Valve Fits All Sizes

HT SERIES Halotron I

Halotron I is an EPA approved clean agent which discharges as a rapidly evaporating liquid, leaving no residue. It effectively extinguishes Class A, B and C fires and is intended for use in areas formerly protected by Halon 1211.

Model
Number
Nominal
Capacity
Shipping
Weight
Cylinder
Diameter
Overall
Height
Overall
Width
UL
Rating
Standard
Bracket*
Optional
Bracket*
MP2½
MP5
MP5-A
MP6
MP10
MP20
2½ lbs.
5 lbs.
5 lbs.
6 lbs.
10 lbs.
20 lbs.
5½ lbs.
9 lbs.
9 lbs.
12 lbs.
18 lbs.
38 lbs.
3 in.
4¼ in.
4¼ in.
5 in.
5 in.
7 in.
145/8 in.
15¼ in.
16 in.
16 in.
20 in.
23¼ in.
5¾ in.
7¼ in.
7¼ in.
7¾ in.
7¾ in.
10¼ in.
1A-10B:C
2A-10B:C
3A-40B:C
3A-40B:C
4A-60B:C
20A-120B:C
817
1521
1521
5525
5525
1007
860
B-2, 818, 821, 860
821, 860
808, 862
B-2, 846, 862
864
DC2½
DC5
DC6
DC10
DC20
2½ lbs.
5½ lbs.
6 lbs.
10 lbs.
20 lbs.
5½ lbs.
9½ lbs.
13 lbs.
18 lbs.
38 lbs.
3 in.
4¼ in.
5 in.
5 in.
7 in.
145/8 in.
15¼ in.
16¼ in.
20 in.
23¼ in.
5¾ in.
7¾ in.
8½ in.
7¼ in.
10¼ in.
10B:C
40B:C
40B:C
60B:C
120B:C
817
1521
1007
5525
1007
860
B2, 818, 821, 860
808, 862
B-2, 846, 862
864
WC-6L6 liters12 lbs.7 in.25 in.9 in.2A:lB:C:K1007864
PW2½2½ gal.7½ lbs.7 in.24½ in.9 in.2A1007B1, 864
WM2½2½ gal.9 lbs.7 in.28 in.14 in.2A:C1007864
CD5
CD1O
CD15
CD20
5 lbs.
10 lbs.
15 lbs.
20 lbs.
14 lbs.
28¼ lbs.
37¾ lbs.
50¾ lbs.
5¼ in.
7 in.
7 in.
8 in.
17¾ in.
24 in.
30 in.
30 in.
8¼ in.
12 in.
12 in.
13 in.
5-B:C
10-B:C
10-B:C
10-B:C
546
575
575
577
862
864
864
864
* NOTE: Standard brackets are included with all extinguishers at no additional cost. If specified, optional brackets are only available at additional cost. All the standard and optional brackets are designed to accommodate Larsen’s extinguishers. While most comparably sized extinguishers usually will function with the brackets at right, Larsen’s cannot assume responsibility for variations in cylinder dimensions among various extinguisher suppliers.