Babcock Davis Smoke Vents

Aluminum Smoke Vents

Babcock-Davis galvanized steel smoke vents are manufactured to automatically open when a fusible link reaches a certain temperature, allowing heat and smoke to escape during a fire. They are spring operated with shock absorbers to slowly open against wind or snow load. Smoke vents can also be equipped to open electrically.

aluminum single smoke vent | Babcock Davis Smoke Vents for Fire Safety at BL Wilcox
aluminum double smoke vent
Babcock Davis Smoke Vents for Fire Safety at BL Wilcox

Aluminum Smoke Vent Specs

Cover & Liner:11-gauge aluminum cover with an 18-gauge aluminum liner
Curb:11-gauge aluminum, Optional: Double wall curb at exterior
Hinge:Tamper-proof hinge contained within hatch as part of a spring assembly
Latch:Fusible link standard. UL listed models – zinc coated pyrolatch assembly with inside and outside manual releases
Spring:Greased compression springs enclosed in telescopic tubes, which counterbalance the door to require no more than 10 pounds of opening force
Hardware:Zinc-coated steel, Optional: Stainless steel
Insulation:1″ thick rigid insulation in cover and 1-1/2″ at curb perimeter
UL listing:Both the fusible melt-out link and McCabe electric/thermal link are UL listed. See size chart below for UL/FM listed models
Mounting Flange:3-1/2″
Finish:Mill
Babcock Davis Smoke Vents for Fire Safety at BL Wilcox

We also offer Domed Smoke Vent Models. Contact us for more information.

Galvanized Steel Smoke Vents

Babcock-Davis galvanized steel smoke vents are manufactured to automatically open when a fusible link reaches a certain temperature, allowing heat and smoke to escape during a fire. They are spring operated with shock absorbers to slowly open against wind or snow load. Smoke vents can also be equipped to open electrically.

galvanized steel single smoke vent | Babcock Davis Smoke Vents for Fire Safety at BL Wilcox
galvanized steel double smoke vent

Galvanized Steel Smoke Vent Specs

Cover & Liner:14 gauge galvanized steel cover with a 22 gauge galvanized steel liner
Curb:14 gauge galvanized steel Optional: double wall curb at exterior
Hinge:Tamperproof hinge contained within hatch as part of a spring assembly
Latch:Fusible link standard. UL listed models – zinc coated pyrolatch assembly with inside and outside manual releases
Spring:Greased compression springs enclosed in telescopic tubes, which counterbalance the door to require no more than 10 lbs. of opening force
Hardware:Zinc-coated steel. Optional: stainless steel
Insulation:1″ thick rigid insulation in cover and 1-1/2″ at curb perimeter
Mounting Flange:3-1/2″
UL listing:Both the fusible melt-out link and McCabe electric/thermal link are UL listed. See size chart below for UL/FM listed models
Finish:Factory applied powder coat

Diagrams and Sizes – Aluminum and Steel Smoke Vents

Single Leaf Smoke Vent Diagram

Single Leaf Smoke Vent Diagram
Standard Sizes
(mm)
width x height
Standard Sizes
(inches)
width x height
610 x 61024 x 24
762 x 76230 x 30
762 x 121930 x 54
762 x 243830 x 96
914 x 61036 x 24
914 x 76236 x 30
914 x 91436 x 36
914 x 243836 x 96
All units are hinged on the second dimension (length).
Rough opening required = hatch size
*Double door construction

Double Leaf Smoke Vent Diagram

Double Leaf Smoke Vent Diagram
Standard Sizes
(mm)
width x height
Standard Sizes
(inches)
width x height
1219 x 121936 x 96
1219 x 121948 x 48*
1219 x 152448 x 60*
1219 x 182848 x 72*
1219 x 243848 x 96*
1524 x 152460 x 60*
1524 x 182860 x 72*
1524 x 243860 x 96*
All units are hinged on the second dimension (length).
Rough opening required = hatch size
*Double door construction